Skip to main content

Fire rated windows

Fire rated aluminium windows, EI30 and higher

Fixed and opening fire rated windows for external walls, internal walls and escape routes, fabricated in aluminium and steel systems in Latvia.

Free project consultation
Manufactured in Liepāja, Latvia
3000+ completed projects
Reply within 1–2 business days

Fire rated windows are needed where a window sits close to a boundary, next to an escape stair or in a wall between fire compartments. We fabricate fixed and opening fire rated windows that keep the same look as the standard windows on the rest of the building.

Send elevations or a window schedule with the required fire classes and we reply with a proposal and price within 1–2 working days.

Opening fire rated windows

Procural PE78EI EI30 TT is a tilt-turn fire rated window up to 1380 × 2760 mm and 200 kg per sash, with sound insulation up to Rw 45 dB. Schüco AWS 70 FR 30 is a 70 mm EI30/EW30 window with CE marking to EN 16034, self-closing locking and watertightness class 9A.

Fixed fire rated windows and external walls

The fixed Procural PE78EI EI30 window reaches Uw 0.9 W/(m²K) with a 78 mm frame and sizes up to 1300 × 2500 mm. Aluprof MB-86N EI provides EI30 windows with Uw from 0.86 W/(m²K), so fire rated windows can meet the same energy targets as the rest of the facade.

Steel fire rated windows

For slim steel sightlines, Jansen Economy 50 windows are available in steel and stainless steel, for heritage buildings and projects where the architect specifies steel.

Fire rated windows: common questions

Can a fire rated window be opened?

Yes. Procural PE78EI EI30 TT and Schüco AWS 70 FR 30 are opening fire rated windows. They close and lock automatically or are kept closed in a fire, depending on the system and the building's fire strategy.

When do I need a fire rated window?

Typically when the window is close to a site boundary or another building, next to an escape stair, or in a wall between fire compartments. The exact requirement follows the national building rules and the fire strategy.

What is the difference between a 30 minute and a 60 minute fire rated window?

The number is the time in minutes that the window keeps its integrity (E) and insulation (I) in a standard fire test to EN 1364-1, classified to EN 13501-2.

Send us your window schedule

Tell us the sizes, opening types and fire classes, or send elevations. We reply with a proposal and price within 1–2 working days.

Request a quote
Call